Dreve
FotoDent Denture
Dental/Biocompatible
Full and partial denture prosthetics; Open 385-405nm
Full specifications
Mechanical
- Tensile strength
- 78 MPa
- Elongation at break
- 14 %
- Flexural strength
- 110 MPa
- Flexural modulus
- 2600 MPa
- Izod impact (notched)
- 42 J/m
- Shore hardness
- 84D
- Compressive strength
- 92 MPa
Thermal
- HDT @ 0.45 MPa
- 82 °C
- HDT @ 1.82 MPa
- 68 °C
- Glass transition
- 84 °C
- Max service temp
- 66 °C
Curing & print
- Viscosity @ 25°C
- 490 cP
- Cure wavelength
- 385-405nm nm
- Post-cure
- 20 min PCU 90 UV with inert gas
- Shrinkage / accuracy
- 0.70%
- Water-washable
- No
Physical
- Density
- 1.15 g/cm³
- Available colors
- Pink Translucent
- Biocompatibility
- Class IIa medical device denture base